Commit 8daa6253 authored by Aleksander Kleczek's avatar Aleksander Kleczek
Browse files

Refine table headings and formatting in 38533_excerpt.md for clarity and consistency

parent 8a90c9a3
Loading
Loading
Loading
Loading
+16 −18
Original line number Diff line number Diff line
@@ -1507,8 +1507,7 @@ Message contents are according to TS 38.508-1 \[14\] clause 7.3 with the followi

Table 4.3.2.2.1.5-1 defines the primary level settings for contention based random access test in FR1 for PSCell in EN-DC. Table 4.3.2.2.1.5-2, Table 4.3.2.2.1.5-3 and Table 4.3.2.2.1.5-4 define the Absolute power limits, Relative power limits and uplink timing error limits respectively, and all include test tolerances.

Table 4.3.2.2.1.5-1: General test parameters for contention based random access test\
in FR1 for PSCell in EN-DC
Table: Table 4.3.2.2.1.5-1: General test parameters for contention based random access test in FR1 for PSCell in EN-DC

| Parameter |  |  | Unit | Test 1 | Comments |
|--|------|-------------|:--------:|:-----------------:|:---------------:|
@@ -1592,7 +1591,7 @@ Test 7: Correct behaviour when contention resolution timer expires:

\- The transmit timing of the PRACH transmission shall be within the accuracy specified in Table 4.3.2.2.1.5-4.

Table 4.3.2.2.1.5-2: Absolute power tolerance Test requirements
Table: Table 4.3.2.2.1.5-2: Absolute power tolerance Test requirements

| Conditions | Tolerance |
|------------|:---------:|
@@ -1600,7 +1599,7 @@ Table 4.3.2.2.1.5-2: Absolute power tolerance Test requirements

`<br />`{=html}

Table 4.3.2.2.1.5-3: Relative power tolerance Test requirements
Table: Table 4.3.2.2.1.5-3: Relative power tolerance Test requirements

| **Power step ∆P (Up or down)**`<br />`{=html}**(dB)** | **PRACH (dB)** |
|-------------------------------------------------------|:--------------:|
@@ -1608,7 +1607,7 @@ Table 4.3.2.2.1.5-3: Relative power tolerance Test requirements

`<br />`{=html}

Table 4.3.2.2.1.5-4: T~e~ Timing error Test requirements
Table: Table 4.3.2.2.1.5-4: T~e~ Timing error Test requirements

|  |  |  |  |
|--|:----------------:|:----------------:|:-------------------:|
@@ -1655,8 +1654,7 @@ The normative reference for this requirement is TS 38.133 \[6\] clause 6.2.2 and

This test can be run in the configurations defined in Table 4.3.2.2.2.4.1-1.

Table 4.3.2.2.2.4.1-1: Non-contention based random access test\
in FR1 for PSCell in EN-DC supported test configurations
Table: Table 4.3.2.2.2.4.1-1: Non-contention based random access test in FR1 for PSCell in EN-DC supported test configurations

| Test Case ID | Test Config Index | Description |
|--|------------|------------------------------------------------|
@@ -1670,7 +1668,7 @@ in FR1 for PSCell in EN-DC supported test configurations

Configure the test equipment and the DUT according to the parameters in Table 4.3.2.2.2.4.1-2.

Table 4.3.2.2.2.4.1-2: Initial conditions for Non-contention based random access test in FR1 for EN-DC
Table: Table 4.3.2.2.2.4.1-2: Initial conditions for Non-contention based random access test in FR1 for EN-DC

| Parameter | Value |  | Comment |
|--|---------|---------------------|-----------------------------|
@@ -1744,7 +1742,7 @@ For this test two cells are used, an E-UTRA serving cell (PCell) and an NR FR1 P

Message contents are according to TS 38.508-1 \[14\] clause 4.6.1 with the following exceptions.

Table 4.3.2.2.2.4.3-0: Common Exception messages
Table: Table 4.3.2.2.2.4.3-0: Common Exception messages

| Default Message Contents |  |
|--|-------------------------------------------|
@@ -1754,7 +1752,7 @@ Table 4.3.2.2.2.4.3-0: Common Exception messages

`<br />`{=html}

Table 4.3.2.2.2.4.3-1: RACH-ConfigCommon for Non-contention Based Random Access
Table: Table 4.3.2.2.2.4.3-1: RACH-ConfigCommon for Non-contention Based Random Access

| Derivation Path: TS 38.508-1 \[14\], Table 4.6.3-128 |  |  |  |
|--|-----------------|-------------|----------|
@@ -1772,7 +1770,7 @@ Table 4.3.2.2.2.4.3-1: RACH-ConfigCommon for Non-contention Based Random Access

`<br />`{=html}

Table 4.3.2.2.2.4.3-2: RACH-ConfigDedicated for Non-contention Based Random Access
Table: Table 4.3.2.2.2.4.3-2: RACH-ConfigDedicated for Non-contention Based Random Access

| Derivation Path: TS 38.508-1 \[14\], Table 4.6.3-129 |  |  |  |
|--|-----------------|-------------|----------|
@@ -1803,7 +1801,7 @@ Table 4.3.2.2.2.4.3-2: RACH-ConfigDedicated for Non-contention Based Random Acce

`<br />`{=html}

Table 4.3.2.2.2.4.3-3: RACH-ConfigGeneric for Non-contention Based Random Access
Table: Table 4.3.2.2.2.4.3-3: RACH-ConfigGeneric for Non-contention Based Random Access

| Derivation Path: TS 38.508-1 \[14\], Table 4.6.3-130 |  |  |  |
|--|-----------------|-------------|----------|
@@ -1820,7 +1818,7 @@ Table 4.3.2.2.2.4.3-3: RACH-ConfigGeneric for Non-contention Based Random Access

`<br />`{=html}

Table 4.3.2.2.2.4.3-4: *ServingCellConfigCommon* for Non-contention Based Random Access
Table: Table 4.3.2.2.2.4.3-4: *ServingCellConfigCommon* for Non-contention Based Random Access

| Derivation Path: TS 38.508-1 \[14\], Table 4.6.3-168 |  |  |  |
|--|-----------------|-------------|----------|
@@ -1831,7 +1829,7 @@ Table 4.3.2.2.2.4.3-4: *ServingCellConfigCommon* for Non-contention Based Random

`<br />`{=html}

Table 4.3.2.2.2.4.3-5: CellGroupConfig for Non-contention Based Random Access
Table: Table 4.3.2.2.2.4.3-5: CellGroupConfig for Non-contention Based Random Access

|  |  |  |  |
|--|:----------------|:-----------|:----------|
@@ -1863,7 +1861,7 @@ Table 4.3.2.2.2.4.3-5: CellGroupConfig for Non-contention Based Random Access

Table 4.3.2.2.2.5-1 defines the primary level settings for non-contention based random access test in FR1 for PSCell in EN-DC. Table 4.3.2.2.2.5-2, Table 4.3.2.2.2.5-3 and Table 4.3.2.2.2.5-4 define the Absolute power limits, Relative power limits and uplink timing error limits respectively, and all include test tolerances.

Table 4.3.2.2.2.5-1: General test parameters for non-contention\
Table: Table 4.3.2.2.2.5-1: General test parameters for non-contention\
based random access test in FR1 for PSCell in EN-DC

| Parameter |  |  | Unit | Test 1 | **Test 2** | **Comments** |
@@ -1946,7 +1944,7 @@ Test 4: Correct behaviour when not receiving Random Access Response:

\- The transmit timing of all PRACH transmissions shall be within the accuracy specified in Table 4.3.2.2.2.5-4.

Table 4.3.2.2.2.5-2: Absolute power tolerance Test requirements
Table: Table 4.3.2.2.2.5-2: Absolute power tolerance Test requirements

| **Conditions** | **Tolerance** |
|----------------|:-------------:|
@@ -1954,7 +1952,7 @@ Table 4.3.2.2.2.5-2: Absolute power tolerance Test requirements

`<br />`{=html}

Table 4.3.2.2.2.5-3: Relative power tolerance Test requirements
Table: Table 4.3.2.2.2.5-3: Relative power tolerance Test requirements

| **Power step ∆P (Up or down) (dB)** | **PRACH (dB)** |
|-------------------------------------|:--------------:|
@@ -1962,7 +1960,7 @@ Table 4.3.2.2.2.5-3: Relative power tolerance Test requirements

`<br />`{=html}

Table 4.3.2.2.2.5-4: T~e~ Timing error Test requirements
Table: Table 4.3.2.2.2.5-4: T~e~ Timing error Test requirements

|  |  |  |  |
|--|:----------------:|:----------------:|:-------------------:|