Large differences in SBA DirAC azimuth angle causing noticeable difference in SBA downmix
Basic info
Bug description
Large differences in SBA DirAC azimuth angle between float and BASOP branch causing noticeable difference in SBA downmix.
Ways to reproduce
IVAS_cod.exe -sba 3 48000 48 ..\scripts\testv\stv3OA48c.wav bit
SBA downmix 2nd channel (float):
SBA downmix 2nd channel (BASOP):
The difference in azimuth angle in the corresponding frame and band is around 30 degrees.
(Clear steps or refer to a failing automated test, e.g. with a pipeline link)
Edited by TYAGIRIS