Large differences in SBA DirAC azimuth angle causing noticeable difference in SBA downmix

Basic info

  • Encoder (float):1bde096f
  • Decoder: 70381f87

Bug description

Large differences in SBA DirAC azimuth angle between float and BASOP branch causing noticeable difference in SBA downmix.

Ways to reproduce

IVAS_cod.exe -sba 3 48000 48 ..\scripts\testv\stv3OA48c.wav bit

SBA downmix 2nd channel (float): image

SBA downmix 2nd channel (BASOP): image

The difference in azimuth angle in the corresponding frame and band is around 30 degrees.

(Clear steps or refer to a failing automated test, e.g. with a pipeline link)

Edited Dec 13, 2024 by TYAGIRIS