Skip to content

Large differences in SBA DirAC azimuth angle causing noticeable difference in SBA downmix

Basic info

Bug description

Large differences in SBA DirAC azimuth angle between float and BASOP branch causing noticeable difference in SBA downmix.

Ways to reproduce

IVAS_cod.exe -sba 3 48000 48 ..\scripts\testv\stv3OA48c.wav bit

SBA downmix 2nd channel (float): image

SBA downmix 2nd channel (BASOP): image

The difference in azimuth angle in the corresponding frame and band is around 30 degrees.

(Clear steps or refer to a failing automated test, e.g. with a pipeline link)

Edited by TYAGIRIS