Skip to content

Energy leakage in IGF tiles for MDCT-stereo @64kbps SWB

Basic info

  • Float reference:
  • Fixed point:

Bug description

There is an energy leaking to subsequent frames in IGF bands from 10-12kHz for item am1aa1s09 that cause the onsets to have different timbre. This can be seen for many onsets. An examples shown here for timestamps 0.520 sec and 1.600 sec

Screenshot_2025-01-22_at_16.50.16

float version:

Screenshot_2025-01-22_at_16.50.47

appart from that there are serious noise filling differences between the two versions, this is something observed throughout most of the files reported.

Ways to reproduce

Box folder: ...\Box_EXTERNAL_IVAS_BASOP_VERIFICATION\issues\issue-1214

./IVAS_cod -stereo -max_band SWB 64000 32 am1aa1s09_32.wav out.192
./IVAS_dec stereo 32 out.192 am1aa1s09.dec.wav
Edited by fotopoulou