Switching artifact worse in rate switching selection test MASA item with float end to BASOP dec
Basic info
- Float reference:
- Fixed point:
Bug description
Specifically with float encoder to BASOP decoder, this rate switching case has a severely emphasized switching artifact towards the end of the file. See figure below.
Ways to reproduce
Box folder: ...\Box_EXTERNAL_IVAS_BASOP_VERIFICATION\issues\issue-1768
Files are in Box folder
IVAS_cod -masa 2 BASOP_Selection_P800-9a_cat4.met -max_band swb generic_start_13k2_20frames.bin 48 BASOP_Selection_P800-9a_cat4.wav test_2417.bs
IVAS_dec BINAURAL 48 test_2417.bs 2417_BASOP_Selection_P800-9a_cat4.wav_generic_start_13k2_20frames_48-48___BINAURAL.wav
Edited by Tapani Pihlajakuja