Large differences between ivas-float-update and BASOP with object editing in OSBA

Basic info

  • Float reference:
    • Encoder (float): b1c0bbd9
    • Decoder (float):b1c0bbd9
  • Fixed point:
    • Decoder (fixed): a6e2340b

Bug description

The output of the two decoder differs strongly when object editing is active.

Ways to reproduce

command line

./IVAS_cod -ism_sba 4 3 ../scripts/testv/stvISM1.csv ../scripts/testv/stvISM2.csv ../scripts/testv/stvISM3.csv ../scripts/testv/stvISM4.csv 256000 48 ../scripts/testv/stvOSBA_4ISM_3OA48c.wav bit

./IVAS_dec -obj_edit NULL BINAURAL 48 ivas-float-update/bit dec.wav

The differences appear also with the editing-instructions file and with BINAURAL_ROOM_IR or FOA output.

Assignee Loading
Time tracking Loading