OSBA 160 kbps: Clicks in Concealment
Basic info
Bug description
For the decoded output, there are at a few instances clearly audible clicks in channel 5 (i.e. the first SBA component = the omni signal).
BASOP:
It's audible at e.g. 0.48s and 1.5s. The issue is not there in the float decoder.
Ways to reproduce
- ./IVAS_cod_flt_ref -ism_sba 4 2 experiments/basop-verification/ISM4SBA2/proc_input/4-overlapping-identical-talkers_sp-rot.wav.0.csv experiments/basop-verification/ISM4SBA2/proc_input/4-overlapping-identical-talkers_sp-rot.wav.1.csv experiments/basop-verification/ISM4SBA2/proc_input/4-overlapping-identical-talkers_sp-rot.wav.2.csv experiments/basop-verification/ISM4SBA2/proc_input/4-overlapping-identical-talkers_sp-rot.wav.3.csv -max_band FB 160000 48 experiments/basop-verification/ISM4SBA2/proc_input/4-overlapping-identical-talkers_sp-rot.wav out/ISM4SBA2--4-overlapping-identical-talkers_sp-rot--160000.192
- eid-xor -vbr -fer out/ISM4SBA2--4-overlapping-identical-talkers_sp-rot--160000.192 error_patterns/ISM4SBA2--4-overlapping-identical-talkers_sp-rot--160000_ep.192 out/ISM4SBA2--4-overlapping-identical-talkers_sp-rot--160000.fer.192
- ./IVAS_dec_fx EXT 48 out/ISM4SBA2--4-overlapping-identical-talkers_sp-rot--160000.fer.192 out/ISM4SBA2--4-overlapping-identical-talkers_sp-rot--160000.fer.dec.fx.wav
- ./IVAS_dec_flt_ref EXT 48 out/ISM4SBA2--4-overlapping-identical-talkers_sp-rot--160000.fer.192 out/ISM4SBA2--4-overlapping-identical-talkers_sp-rot--160000.fer.dec.flt.wav
- wav-diff --no-fail --print-ctest-measurement out/ISM4SBA2--4-overlapping-identical-talkers_sp-rot--160000.fer.dec.flt.wav out/ISM4SBA2--4-overlapping-identical-talkers_sp-rot--160000.fer.dec.fx.wav
Edited by multrus