Large differences in SBA DirAC azimuth angle causing noticeable difference in SBA downmix
# Basic info <!--- Add commit SHA used to reproduce --> - Encoder (float):1bde096f - Decoder: 70381f87 # Bug description Large differences in SBA DirAC azimuth angle between float and BASOP branch causing noticeable difference in SBA downmix. # Ways to reproduce IVAS_cod.exe -sba 3 48000 48 ..\scripts\testv\stv3OA48c.wav bit SBA downmix 2nd channel (float): ![image](/uploads/9d0f38470920769c05e6354663a47e98/image.png) SBA downmix 2nd channel (BASOP): ![image](/uploads/7fd4918058211ba635a5a29eee7c9a36/image.png) The difference in azimuth angle in the corresponding frame and band is around 30 degrees. (Clear steps or refer to a failing automated test, e.g. with a pipeline link) <!--- Below are labels that will be added but are not shown in description. This is a template to help fill them. Add further information to the first row and remove and add labels as necessary. -->