Admin message

WARNING! Gitlab maintenance operation scheduled for Thursday, 7 May between 12:00 and 14:00 (CET). During this time window, short service interruptions (less than 5 minutes) may occur. Thank you in advance for your understanding.

Signal cuts with BASOP encoder - float decoder combination in MASA DTX rate switching
# Basic info <!--- Add commit SHA used to reproduce --> - Float reference: - Encoder (float): - Decoder (float): b63c033f6c - Fixed point: - Encoder (fixed): f66bba2c3c - Decoder (fixed): # Bug description There are some impulses and signal missing with combination of BASOP encoder and float decoder. See plots below: ![Screenshot_2025-04-10_at_11.01.29](/uploads/5e5a49700307d22e765ae6951e98b63f/Screenshot_2025-04-10_at_11.01.29.png) This does not happen with any other combination of BASOP and float binaries. # Ways to reproduce Box folder: ...\Box_EXTERNAL_IVAS_BASOP_VERIFICATION\issues\issue-1467 <!-- Commandline or script --> Use the command line with files from Box. ```bash IVAS_cod -masa 2 BASOP_Selection_P800-8b_cat5.met -max_band fb -dtx generic_start_128k_20frames.bin 48 BASOP_Selection_P800-8b_cat5.wav test_2192.bs IVAS_dec_ref EXT 48 test_2192.bs 2192_BASOP_Selection_P800-8b_cat5.wav_generic_start_128k_20frames_48-48___EXT.wav ``` <!--- Below are labels that will be added but are not shown in description. This is a template to help fill them. Add further information to the first row and remove and add labels as necessary. -->
issue