Spike in BASOP encoded signal of MASA selection material
# Basic info
<!--- Add commit SHA used to reproduce -->
- Float reference:
- Encoder (float): b63c033f6c
- Decoder (float): b63c033f6c
- Fixed point:
- Encoder (fixed): a6ac79717d
- Decoder (fixed): a6ac79717d
# Bug description
There is an audible and visible "spike" in BASOP encoded signal (at 4 s shown below) using the provided input and command line. There is a transient also in pure float version but it is significantly emphasized with BASOP encoder.

# Ways to reproduce
Box folder: ...\Box_EXTERNAL_IVAS_BASOP_VERIFICATION\issues\issue-1499
<!-- Commandline or script -->
Following command line and input from Box
```bash
IVAS_cod -masa 2 BASOP_Selection_MUSHRA-7ad_s04.met -max_band swb -dtx 16400 48 BASOP_Selection_MUSHRA-7ad_s04.wav test_0971.bs
IVAS_dec EXT 48 test_0971.bs 0971_BASOP_Selection_MUSHRA-7ad_s04.wav_16k4_48-48___EXT.wav
```
<!--- Below are labels that will be added but are not shown in description. This is a template to help fill them.
Add further information to the first row and remove and add labels as necessary. -->
issue