MASA 2TC Rendering to Mono: Large diff signal < 12 kHz
# Basic info <!--- Add commit SHA used to reproduce--> - Float reference: - Renderer (float): efe53129c9ed87a5067dd0a8fb9dca41db9c4add - Fixed point: - Renderer (fixed): ac9000522338d839508dfc57f3de4633e6f0ed0e # Bug description For rendering MASA 2TC to mono, there are significant differences below 12 kHz between BASOP and Float: BASOP: **![Bildschirmfoto 2026-02-14 um 21.31.40.png](/uploads/9ffe6d0fe7ca4fc7e7fb60fa531d24ca/Bildschirmfoto_2026-02-14_um_21.31.40.png){width=1387 height=887}** **Float:** ![Bildschirmfoto 2026-02-14 um 21.31.50.png](/uploads/843224dc8701dbf334a31cfbb2bbc00a/Bildschirmfoto_2026-02-14_um_21.31.50.png){width=1387 height=887} # Ways to reproduce <!--Commandline or script--> ```bash IVAS_rend -i ltv48_MASA2TC.wav -im ltv48_MASA2TC.met -if masa2 -of mono -o out.wav ``` <!--- Below are labels that will be added but are not shown in description. This is a template to help fill them. Add further information to the first row and remove and add labels as necessary.-->