Limiter updates for release constant for 8kHz, 16kHz, and 32kHz sample rates
-
Update to reduce MLD for High MLD cases (SBA PLC test cases)
-
EVS 26.444 BE test passes.
-
decoder pytests:
MLD scores:
Original inputs: 562 failed, 374 skipped
MLD > 10: 3
MLD > 5 : 36
MLD < 5 : 523
+10dB inputs: 562 failed, 374 skipped
MLD > 10: 48
MLD > 5 : 146
MLD < 5 : 368
-10dB inputs: 562 failed, 374 skipped
MLD > 10: 0
MLD > 5 : 7
MLD < 5 : 555 -
encoder pytests results:
MLD scores:
Original inputs: 562 tests:
MLD > 10: 18
MLD > 5 : 67
MLD < 5 : 477
+10dB inputs: 562 tests:
MLD > 10: 69
MLD > 5 : 122
MLD < 5 : 371
-10dB inputs: 562 tests:
MLD > 10: 5
MLD > 5 : 24
MLD < 5 : 533
Edited by Sandesh Venkatesh