@@ -596,7 +596,8 @@ module _3gpp-common-trace {
        enum VENDORMAXIMUM;
      }
      default MAXIMUM;
      description "It specifies the trace depth. The attribute is applicable only for Trace.";
      description "It specifies the trace depth. The attribute is 
        applicable only for Trace.";
      reference "Clause 5.3 of 3GPP TS 32.422.";
    }  
    
@@ -856,13 +857,13 @@ module _3gpp-common-trace {
        measurementPeriodLte, collectionPeriodM6LTE, collectionPeriodM7LTE,
        collectionPeriodRRMUMTS, measurementPeriodUMTS) and the number of 
        reports (reportAmountM4NR, reportAmountM5NR, reportAmountM6NR, 
        reportAmountM7NR, reportAmountM4LTE, reportAmountM5LTE, reportAmountM6LTE,
        reportAmountM7LTE).  If no collection
        period is configured for M5 in UMTS, all available measurements are
        logged according to RRM configuration.
        reportAmountM7NR, reportAmountM4LTE, reportAmountM5LTE, 
        reportAmountM6LTE, reportAmountM7LTE).  If no collection
        period is configured for M5 in UMTS, all available measurements
        ar elogged according to RRM configuration.
        
        - Measurements M8 and M9 in NR or LTE are reported according to configured 
        M1 and/or M6 related UE measurement reporting. 
        - Measurements M8 and M9 in NR or LTE are reported according to 
        configured M1 and/or M6 related UE measurement reporting. 
        ";
        
   leaf listOfMeasurements {
@@ -883,8 +884,9 @@ module _3gpp-common-trace {
        enum M8;
        enum M9;
      }
      description "It specifies the UE measurements that shall be collected in
        an Immediate MDT job. The attribute is applicable only for Immediate MDT.";
      description "It specifies the UE measurements that shall be 
        collected in an Immediate MDT job. The attribute is 
        applicable only for Immediate MDT.";
      reference "Clause 5.10.3 of 3GPP TS 32.422.";
    }

@@ -899,8 +901,8 @@ module _3gpp-common-trace {
        enum ALL_CONFIGURED_RRM_FOR_LTE;
        enum ALL_CONFIGURED_RRM_FOR_UMTS;
      }
      description "It specifies whether periodic or event based measurements
        should be collected.
      description "It specifies whether periodic or event based 
        measurements should be collected.
        The attribute is applicable only for Immediate MDT and when the
        listOfMeasurements is configured for M1 (for both UMTS and LTE)
        or M2 (only for UMTS).";
@@ -1034,9 +1036,10 @@ module _3gpp-common-trace {
        enum 1min;
      }
      mandatory true;
      description "It specifies the measurement period for the Data Volume (M4) and
        Scheduled IP throughput measurements (M5) for LTE MDT taken by the eNB.
        The attribute is applicable only for Immediate MDT.";
      description "It specifies the measurement period for the 
        Data Volume (M4) and Scheduled IP throughput measurements
        (M5) for LTE MDT taken by the eNB. The attribute is 
        applicable only for Immediate MDT.";
      reference "Clause 5.10.23 of 3GPP TS 32.422.";
    }
    
@@ -1346,7 +1349,8 @@ module _3gpp-common-trace {
      Based on the value configured for attribute jobType in IOC TraceJob, 
      different attributes are available. In case of LOGGED_MDT_ONLY, the 
      attributes reportType, eventListForEventTriggeredMeasurement, 
    eventThresholdL1, hysteresisL1, timeToTriggerL1, areaConfigurationForNeighCells
      eventThresholdL1, hysteresisL1, timeToTriggerL1, 
      areaConfigurationForNeighCells
      and npnIdentityList are applicable. In case of LOGGED_MBSFN_MDT, 
      the attribute mbsfnAreaList is applicable. 
      The optional attribute plmnList allows to specify the PLMNs where 
@@ -1354,19 +1358,22 @@ module _3gpp-common-trace {
      the optional attribute areaConfigurationForNeighCell allows to specify 
      the area for which UE is requested to perform measurements logging for 
      neighbour cells which have list of frequencies.  For logged MDT in UMTS 
    and LTE, the reporting is periodical. Parameter loggingInterval determines 
    the interval between the reports and parameter loggingDuration determines 
    how long the configuration is valid meaning after this duration has passed 
    no further reports are sent. In NR, the reporting can be periodical or event 
      and LTE, the reporting is periodical. Parameter loggingInterval 
      determines  the interval between the reports and parameter 
      loggingDuration determines how long the configuration is valid 
      meaning after this duration has passed no further reports are sent. 
      In NR, the reporting can be periodical or event 
      based, determined by parameter reportType. For periodical reporting the 
      same parameters as in LTE and UMTS apply. For event based reporting, 
    parameter eventListForEventTriggeredMeasurement configures the event type, 
    namely 'out of coverage' or 'L1 event'. In case 'L1 event' is selected as 
    event type, the logging is performed according to parameter loggingInterval
    at regular intervals only when the conditions indicated by eventThresholdL1, 
    hysteresisL1, timeToTriggerL1 (defining the thresholds, hysteresis and time 
    to trigger) are met and if UE is 'camped normally' state (TS 38.331, 
    TS 38.304).  In case 'out of coverage' is selected as event type, the
      parameter eventListForEventTriggeredMeasurement configures the event 
      type, namely 'out of coverage' or 'L1 event'. In case 'L1 event' is
      selected as event type, the logging is performed according to 
      parameter loggingInterval at regular intervals only when the
      conditions indicated by eventThresholdL1, 
      hysteresisL1, timeToTriggerL1 (defining the thresholds, hysteresis 
      and time to trigger) are met and if UE is 'camped normally' state 
      (TS 38.331, TS 38.304).  In case 'out of coverage' is selected as 
      event type, the
      logging is performed according to parameter loggingInterval at regular 
      intervals only when the UE is in 'any cell selection' state. 
      Furthermore, logging is performed immediately upon transition from the
@@ -1535,7 +1542,8 @@ module _3gpp-common-trace {
    description "Defines the configuration parameters of IOC 
     TraceJob which are specific for MDT. The attribute 
     anonymizationOfMdtData specifies the level of anonymization 
     of MDT data.  The attribute areaScope defines the area scope of MDT, which is specified in clause 5.10.2 of TS 32.422.  The   
     of MDT data.  The attribute areaScope defines the area scope of MDT, 
     which is specified in clause 5.10.2 of TS 32.422.  The   
     optional attribute sensorInformation allows to 
     specify  the sensor information to include.  Based on the value 
     configured for attribute jobType in IOC TraceJob, the attributes 
@@ -1606,8 +1614,9 @@ module _3gpp-common-trace {

  grouping UECoreMeasConfigGrp {
    description "Represents the UECoreMeasConfig dataType.
      This <<dataType>> defines the aconfiguration parameters of IOC TraceJob
        which are specific for 5GC UE level measurements collection.";
      This <<dataType>> defines the aconfiguration parameters of IOC 
      TraceJob which are specific for 5GC UE level measurements 
      collection.";
    
    leaf-list ueCoreMeasurements {
      type string;
@@ -1615,13 +1624,19 @@ module _3gpp-common-trace {
        The list may include 5GC UE level measurements 
        defined in TS 28.558, or vendor specific measurements.
        
        For 5GC UE level measurements defined in TS 28.558, the name is constructed as follows:
        -	'family.measurementName.subcounter' for measurement type with specified subcounter
        -	'family.measurementName.ALL' for measurement type with all supported subcounters
        -	'family.measurementName' for measurement type without subcounters
        -	'family' for measurement family, including all measurement types and 
        For 5GC UE level measurements defined in TS 28.558, the 
        name is constructed as follows:
        -	'family.measurementName.subcounter' for measurement type 
        with specified subcounter
        -	'family.measurementName.ALL' for measurement type with all 
        supported subcounters
        -	'family.measurementName' for measurement type without 
        subcounters
        -	'family' for measurement family, including all measurement 
        types and 
        the associated subcounters under this family.
        For non-3GPP specified 5GC UE level measurements the name is defined elsewhere.";
        For non-3GPP specified 5GC UE level measurements the name is 
        defined elsewhere.";
    }

    leaf ueCoreMeasGranularityPeriod {
@@ -1674,8 +1689,9 @@ module _3gpp-common-trace {
      }
      default TRACE_ONLY;
      description "It specifies whether the
        TraceJob represents only MDT, Logged MBSFN MDT, Trace, or 5GC UE 
        level measurements job, or a combined job. It also defines the MDT mode.";
        TraceJob represents only MDT, Logged MBSFN MDT, Trace, or 
        5GC UE level measurements job, or a combined job. It also 
        defines the MDT mode.";
      reference "Clause 5.9a of 3GPP TS 32.422.";
    }
    
@@ -1780,10 +1796,10 @@ module _3gpp-common-trace {
        includes the ID type of the target as an enumeration and the ID value.

        The traceTarget shall be 'PUBLIC_ID' in case of a Management Based
        Activation is done to an SCSCFFunction (Serving Call Session Control Function) 
        or PCSCFFunction (Proxy Call Session Control Function). 
        The traceTarget shall be 'UTRAN_CELL' only in case of the UTRAN cell traffic 
        trace function.
        Activation is done to an SCSCFFunction (Serving Call Session 
        Control Function)  or PCSCFFunction (Proxy Call Session Control 
        Function).  The traceTarget shall be 'UTRAN_CELL' only in case 
        of the UTRAN cell traffic trace function.

        The traceTarget shall be 'E-UTRAN_CELL' only in case of E-UTRAN cell
        traffic trace function.